AI in veterinary medicine is no longer a conference topic. It reads radiographs, finds parasite eggs, scans ear and mass cytology, drafts the medical record and screens lumps for cancer risk. Here is what each type of tool does, and how to tell a useful one from a good sales pitch.
The short answer:
AI in veterinary medicine is software trained on thousands of past cases that helps with a job your team already does. Today that means imaging, in-house lab work (cytology, fecal, urine and blood), records, and cancer risk screening for lumps. It makes the work faster and more consistent, and adds a second look that supports accurate results. The veterinarian still makes the call.

How is AI used in veterinary medicine today?

Area What the AI does Examples
Radiographs Flags possible findings and drafts a read, often with a radiologist available for review SignalPET, Vetology AI, Antech RapidRead, Radimal, PicoxIA
Cytology (ear, skin, masses, lymph nodes) Finds bacteria, yeast and inflammatory cells, and flags cells that may be neoplastic Zoetis Vetscan Imagyst (AI Dermatology, AI Masses), IDEXX inVue Dx (ear cytology)
Fecal Detects and identifies parasite ova, cysts and oocysts Zoetis Vetscan Imagyst AI Fecal
Urine Classifies urine sediment: cells, crystals, bacteria, casts IDEXX SediVue Dx, Vetscan Imagyst AI Urine Sediment
Blood Reviews blood smears and cell morphology alongside the CBC IDEXX inVue Dx, Vetscan Imagyst AI Blood Smear
Records and clinical questions Drafts the record from the consult and answers clinical and drug questions with cited sources ScribbleVet and Attending (both from Instinct, drawing on Plumb's)
Cancer risk screening Gives a cancer risk level for dermal and subcutaneous masses before the needle VISTA iQ by HT VET
The list changes fast. Use this map of veterinary AI tools as a guide, not a recommendation, and check what a tool does today before you plan around it.

Imaging: a useful second look

AI radiograph tools flag findings such as a foreign body pattern or an enlarged cardiac silhouette and draft a report in minutes. Most also let you send the study on to a radiologist. That is the right way to use them.

The American College of Veterinary Radiology (ACVR) and the European College of Veterinary Diagnostic Imaging (ECVDI) said in a 2025 joint statement that AI should always be used with a qualified veterinary professional in the loop. Read the AI as a second opinion, not the final report.

AI cytology and the in-house lab

Veterinary AI cytology is where the technology has moved fastest. You load the sample, and the AI does the searching and counting a technician would otherwise do at the microscope. Results come back in minutes, often while the owner is still in the room.
  • Zoetis Vetscan Imagyst scans a slide and runs separate AI apps for fecal parasites, blood smears, skin and ear cytology, urine sediment, and AI Masses for skin masses and lymph nodes. Images can also go to a board certified clinical pathologist for review as an optional service.
  • IDEXX inVue Dx needs no slide. It runs ear cytology and blood morphology.
  • IDEXX SediVue Dx automates urine sediment and has been in clinics for years.
What you gain: consistent counts, less time at the microscope, faster answers. What stays with you: a flagged cell is not a diagnosis. Unusual or high stakes samples still go to a clinical pathologist.

Records and clinical questions

An AI scribe such as ScribbleVet listens to the consult and drafts the record. Scribes save real time, but they write fluently even when they are wrong, so someone reads every note before signing it. Ask the owner before you record the room.

Clinical assistants such as Attending, also from Instinct, answer clinical and dosing questions with cited sources, including Plumb’s. Good for a quick check. The dose you give is still your decision.

Lumps and bumps: AI screening before the needle

Every clinic sees dermal and subcutaneous masses daily, and you can’t tell benign from malignant by feel. A soft, mobile lump on a nine year old dog is probably a lipoma, but mast cell tumors can look like almost anything. The hard part is deciding which masses to sample today.

VISTA iQ is built for that step. It uses Heat Diffusion Imaging technology: benign and malignant tissue show different thermodynamic patterns. A technician or nurse runs a 40 second, non-invasive scan over the mass, and the AI returns a cancer risk level of low, moderate or high in under two minutes. It doesn’t diagnose. It screens. It does not grade a tumor or name a cell type. It helps the team decide which masses go on to aspirate or biopsy first and which masses can go on a monitoring plan.

VISTA iQ scanner beside a tablet showing the scan view

The latest study, published in Veterinary Sciences in 2026 (Dank and colleagues), looked at 1,010 masses from 669 dogs scanned with HT Vista, the first generation scanner that VISTA iQ builds on. On the test set:

  • Sensitivity 92% and specificity 71.8% for benign versus malignant.
  • Negative predictive value 98.1%, adjusted to an assumed 15% malignancy rate. This is the number that matters for a screening tool: a negative result is designed to rule out cancer in the scanned mass.
  • Two separate classifiers run after the benign versus malignant call. One flags mast cell tumors with 94.6% specificity. Its sensitivity for mast cell tumors is 31.8%, so a mast cell tumor flag is a reason to sample, and no flag does not rule a mast cell tumor out.
  • The other flags lipomas with 86.4% sensitivity and 100% specificity, though that specificity rests on only 11 masses that were not lipomas. A lipoma flag is decision support, and cytology confirms what the mass is.

These figures measure different things, so don’t merge them into one accuracy number.

A simple clinic protocol, always applied with clinical judgment:

  1. Low risk: record the result, size and location, and offer a monitoring plan with routine follow-ups.
  2. Moderate risk: aspirate, ideally in the same visit, and read cytology in house or send it out.
  3. High risk: aspirate now and talk the owner through next steps, including biopsy where indicated.

Screening and AI cytology work well together. VISTA iQ helps pick which masses to sample, and in-house cytology or your reference lab tells you what they are. For the full workup, see our vet’s guide to assessing lumps and bumps in dogs.

Six questions to ask before you buy

Before you invest in AI veterinary diagnostics, know that companies developing devices for animals are not required to go through the premarket screening that applies to devices for people. The vetting falls to you. Ask:

  1. What exactly does it output? A risk level, a flagged region, a cell count, a draft note?
  2. Where is the published validation? How many cases, which patients, and against what reference standard (cytology, histopathology, a pathologist)?
  3. Are sensitivity, specificity, NPV and PPV reported separately? One “accuracy” figure hides the trade off. A tool built to rule things out should show strong sensitivity andNPV. A tool that raises alerts should show strong specificity and PPV.
  4. Who runs it and how long does it take? A tool your technicians can run between rooms scales very differently from one that needs the doctor.
  5. Where does the data go? Who owns it, and is it used to retrain the model?
  6. What will you tell the owner? The ACVR and ECVDI recommend telling owners when AI is used in a diagnostic role.

## Will AI in veterinary medicine replace veterinarians?

No. But veterinarians who don’t use AI may be replaced by those who do.

AI moves your time around. The decision stays with you. A scribe can shrink the pile of open records at the end of the day. A lab analyzer can give you a cytology answer while the owner waits. A risk scan can help sort which masses to sample. In every case the veterinarian reviews the result and owns the plan, and the team should feel comfortable overruling the tool.

Rolling out a new tool

Start with one real problem, like “records keep us here late” or “we want to sample more lumps and stop sending patients home with undiagnosed masses.” Pick one owner on the team, usually a lead technician or nurse. Write a one page protocol: when it’s used, who runs it, where the result goes in the record, and what happens next. Review it after 60 to 90 days. For VISTA iQ, the HT Vet Academy has videos, guides and a team certificate.

Talking to owners

Keep it to two sentences. What it does: “This scan gives us a risk level for the lump, which helps us decide what to do next.” Who decides: “The doctor reviews it and we make the plan together.”

Frequently Asked Questions

What is AI in veterinary medicine?

Software trained on past clinical data, usually through machine learning, that helps with tasks such as reading radiographs, analyzing cytology, fecal and urine samples, writing records and screening masses for cancer risk.

How is AI used in veterinary clinics today?

Mostly in imaging, in-house lab analyzers (cytology, fecal, urine and blood), AI scribes and clinical assistants, and point of care cancer risk screening.

Will AI replace veterinarians?

No. It supports judgment, it doesn’t replace it. But veterinarians who don’t use AI may be replaced by those who do. The ACVR and ECVDI say AI should always be used with a qualified veterinary professional in the loop.

Can AI read cytology?

Yes, for defined sample types. Zoetis Vetscan Imagyst, for example, finds and classifies cells in ear, skin, blood, mass and lymph node samples. Unusual or critical cases still go to a clinical pathologist.

Can AI diagnose cancer in dogs?

No. VISTA iQ gives a cancer risk level for dermal and subcutaneous masses, which helps decide which masses to aspirate or biopsy. The diagnosis still comes from cytology or histopathology.

Do owners need to be told when AI is used?

It is recommended. A sentence on what the tool does and who makes the decision is usually enough.

Is AI accurate in veterinary diagnostics?

It depends on the tool and the task, so look for published sensitivity, specificity and predictive values for the exact use. For heat diffusion imaging, the 2026 study (on HT Vista, the scanner VISTA iQ builds on) reported 92% sensitivity, 71.8% specificity and an NPV of 98.1% adjusted to an assumed 15% malignancy rate. Each figure measures something different.

What are the risks of AI in veterinary medicine?

Errors that sound confident, overreliance on the output, and unclear use of clinic data. Keep a veterinarian in the loop, check the published validation, and ask who owns the data.

See how AI screening fits your appointments. Book a free Lunch & Learn